This article applies to:
E-Prime 2.0
Detail
NOTE: This is not the latest version of E-Prime 2.0. Please refer to RELEASE INFO: Using the latest version of E-Prime [30812] for more information.
To determine what version of E-Prime is installed on your computer, see RELEASE INFO: How to determine E-Prime version number [17909].
The following is a partial outline of changes in E-Prime 2.0 by build/date.
E-Prime 2.0.10.182 (2012-02-01)
BUGFIX: Counterbalance causing crash
BUGFIX: Pasting Slide components causing crash
KNOWN ISSUE: / leading character for relative file names results in file not found
E-Prime 2.0.10.181 (2012-01-30)
BUGFIX: CodecConfig File/RenderFile would crash if generate report option unchecked
BUGFIX: Copy/Paste or Drag objects in E-Studio would cause User script area to clear
BUGFIX: Use of OffsetSync would cause objects to terminate early
E-Prime 2.0.10.180 (2012-01-28)
Internal updates for quality
E-Prime 2.0.10.178 (2012-01-24)
Internal updates for quality
E-Prime 2.0.10.174 (2012-01-05)
INFO: Listing of Experiment Advisor Modules [19137]
INFO: ClearAfter not recommended [19126]
INFO: InputMask.TimeLimit (until feedback) option [19098]
ERROR: E-Basic Script Generation uses constants for literal strings [19049]
E-STUDIO: Configuring Task Events [24789]
ERROR: "Object variable or With block variable not set" error message [19041]
E-BASIC: Rte.PreventSystemIdle method [19036]
DATA: DataFile.BaseName attribute [19027]
E-BASIC: ResponseData.SEQD and ResponseData.SEQH properties [19018]
E-BASIC: Rte.AbortExperiment [18968]
AV: StopAfterMode introduced for Movie and Sound objects [18964]
E-BASIC: DisplayDevice.Handle property [18945]
E-Prime installation includes SoundTester application EXPERIMENT DESIGN: SoundTester [22725]
E-BASIC: DisplayDevice.DisplayIndex property [18917]
AV: Ability to suppress audio and video load reports [18880]
INFO: E-Studio experiment author specified version [18874]
AV: Editing the SoundDevice.API for DirectSound, ASIO, CoreAudio, or Chronos [18865]
E-BASIC: SlideMovie and MovieDisplay offers .Status property akin to SoundBuffer.Status [18850]
INFO: Ability to specify a custom data file name for experiment data file [18824]
E-BASIC: ScriptSense Options [18724]
E-BASIC: .NativeHeight and .NativeWidth properties for SlideMovie, SlideImage, MovieDisplay, and ImageDisplay objects [18619]
ERROR: Detection of invalid Refresh Rate [18535]
E-BASIC: Bitwise operations in E-Basic (LShift, RShift, BitwiseAnd) [18531]
AV: DisplayDevice.FlippingEnabled [18483]
INFO: Slide.ActiveObjects property provides ActiveObjects shortcut [18469]
E-BASIC: CGuid introduced to generate smaller code [18402]
E-BASIC: InStrRev function in E-Basic language [18387]
INFO: Property ToolTips shows additional object information in Structure view [18358]
INFO: Ability to specify RefreshRate in DisplayDevice GUI [18279]
INFO: InputMask.TimeLimit (end of proc) option [18043]
INFO: EndResponseAction=Terminate behavior changed [18036]
INFO: E-Studio offers choosing template experiment files when creating new experiments [17959]
INFO: Default frame size lowered to 75% [17951]
INFO: Conditional Exit (Graceful Abort) [17943]
TIMING: PreRelease defaults changed to promote better timing accuracy [17936]
INFO: Legacy Methods to Send Markers to an External Device [17212]
E-BASIC: CColor, Color Object, RteColor provides expanded colors and HTML color listing [17814]
INFO: ResetLoggingProperties reset their logging properties at begin of each Procedure run [17763]
RELEASE INFO: Support for 64-bit Windows Operating Systems [17678]
INFO: Ability to lock aspect ratio for scaling images when using Stretch property [17656]
INFO: Ability to specify multiple correct answers [17284]
INFO: Ability to not have repeated values after shuffle [17189]
INFO: Specifying a Subject number during Startup Info prompts [17161]
DEVICE: Parallel Port Device [17150]
INFO: Ability to Copy/Paste objects in E-Studio [17132]
E-BASIC: Ability to do Mark actions in Script/Inline objects [17004]
ERROR: Script highlighting on compile and runtime errors [16934]
DEVICE: Socket Device supports TCP and UDP communication [16877]
E-BASIC: Expose collection of Procedure child items [16844]
DATA: Procedure FlushDataLog option [16774]
INFO: Ability to log Onset To Onset times [16765]
INFO: Disable all Startup Info Parameters when "ignore all prompts" is set [16623]
INFO: Use / for path separation for E-Objects with filename property [16554]
FEATURE: Output window provides hot links for data file, E-Recovery file, and Experiment Advisor report
FEATURE: Procedure toolbar added to access property pages
FEATURE: Ability for ParallelPortDevice to ToggleBit, SetBit, ResetBit (DEVICE: How To Send Markers Through a Parallel Port [25286])
FEATURE: Ability for ScriptSense choices to appear immediately after typing eb to facilitate easier choosing of constants (E-BASIC: ScriptSense - Function Completion similar to Intellisense (TM) in E-Basic script windows [17565])
FEATURE: E-Prime 2.0 Professional permits unlimited SlideState worksheet tabs
FEATURE: PackageFile Editor adds option for ByRef or ByVal parameters
FEATURE: SocketDevice configured to improve latency of data packets sent
FEATURE: E-Prime SNTP Realtime Clock (TIMING: E-Prime SNTP Realtime Clock [19471])
FEATURE: StartupInfo Editor (OVERVIEW: Modifying StartupInfo using StartupInfo Editor [22727])
FEATURE: COM Ports 1-256 for SerialDevice or SRBOXDevice (INFO: How do I verify the port number being used by the SRBox? [18028])
FEATURE: Ability for GUI and Runtime components to use / character (INFO: Use / for path separation for E-Objects with filename property [16554])
FEATURE: E-Studio Toolbox order of items
FEATURE: StartupInfo Editor Local/Global buttons added to Experiment Object
FEATURE: Ability for paste operations to include Device and Package objects
FEATURE: Support for multiple JoystickDevice objects (INFO: Joystick Device [17152])
FEATURE: Procedure GenerateLabels property (E-STUDIO: Procedure.GenerateLabels Property [28313])
FEATURE: GeneratePreRun and GeneratePostRun properties (TIMING: Pre-Run and Post-Run Generation [22854])
FEATURE: PackageFile Editor offers return value for Routines
FEATURE: Add parameter to SetNextTargetOnsetTime that resets the terminate mode flag
FEATURE: Invoking programs on Tools menu should set current folder to currently loaded experiment
FEATURE: Serial Device allows a WriteByte method (DEVICE: How To Send Markers Through a Serial Port [25287])
FEATURE: Auto Response (E-STUDIO: Auto Response [22738])
FEATURE: Show name of E-Object sub components
FEATURE: Ability for Slide to remove or change order of objects collection
FEATURE: Ability for software debouncing via PortDevice
FEATURE: Abilty to get/set terminate mode via GetTerminateMode and SetTerminateMode
FEATURE: Ability to log when an InputMask IsPending at the end of a procedure
FEATURE: Ability to vary List.Filename with [attrib] reference
FEATURE: Ability to obtain colleciton of attributes and level information on list in E-Basic
FEATURE: Ability to log Weight, Nested, Procedure, Reset/Exit, selection props
FEATURE: Add source color key to GUI ImageDisplay
See Also:
RELEASE INFO: E-Prime 2.0 Change History (2.0 beta to 2.0.1.127) [19386]
RELEASE INFO: E-Prime 2.0 Change History (2.0.8.0 to 2.0.8.89) [19387]
RELEASE INFO: E-Prime 2.0 Change History (2.0.10.183 to 2.0.10.242) [19389]
RELEASE INFO: E-Prime 2.0 Change History (2.0.10.242 to 2.0.10.353) [19548]
RELEASE INFO: E-Prime 2.0 Change History (2.0.10.353 to 2.0.10.356) [19581]
Comments
0 comments
Please sign in to leave a comment.