This article applies to:
E-Prime Extensions for Tobii Pro 3.2
Detail
The following are known issues in the most recent production release of E-Prime Extensions for Tobii Pro 3.2 (version 3.2.1.105). This article is updated when a new version of E-Prime Extensions for Tobii Pro 3.2 is released.
SCRIPTSENSE ISSUES - ScriptSense for EET 3.2 does not offer information when hovering over the functions / commands in script. Additionally, Tobii Pro Lab Members are not currently available with auto-completion in the ScriptSense dropdown. See BUG: E-Prime Extensions for Tobii Pro 3.2 (EET) ScriptSense Issues [29760] for more information on the bug and SCRIPTING: ScriptSense [22873] for ScriptSense information.
OBJECT AFTER TETGAZEDATASAVE - An error occurs if an E-Object is placed after TETGazeDataSave (BUG: E-Objects after TETGazeDataSave cause a Runtime Error [29761]).
WINDOWS 8 / 8.1 INSTALLATION ERRORS - System errors may occur if installing EET Runtime components on Windows 8 / 8.1 (BUG: Error occurs while installing on Win 8 / 8.1 [29762]).
ERROR ON TPLOPEN- An error occurs when not using the default Display name (BUG: Error on TPLOpen when using non-default Display name [30766]).
WINDOWS 7 MEDIA ISSUE- Tobii Pro Lab images may not appear correctly when running on Windows 7 (BUG: Tobii Pro Lab media is not shown correctly when running on Windows 7 [30978]).
TETGAZEREPLAY ISSUE- Gaze replay may not work correctly under certain multiple monitor configurations (BUG: Gaze replay routine does not work correctly on multi-monitor experiments when invoked on opposite monitor of gaze recording [31035]).
EYE TRACKER MANAGER ERROR- An error occurs when attempting to open the application (BUG: Eye Tracker Manager does not open up from TobiiEyeTracker device [34402]).
EYE TRACKER CANNOT START CALIBRATION ERROR- An error occurs during runtime when a display setup is not created in Eye Tracker Manager (ERROR: Runtime error occurs stating that the eye tracker device cannot start calibration [34440]).
TETWAITFORFIXATION VISUAL FEEDBACK - Visual feedback is shown to participants when unspecified (BUG: Unspecified VisualFeedbackColor parameter in TETWaitForFixation still presents visual feedback [31042]).
SETPLACEHOLDER ROUTINE MISSING SOME PARAMETER DESCRIPTIONS- The TobiiProLab_SetPlaceholder PackageFile routine is missing some parameter descriptions (BUG: SetPlaceholder routine missing some parameter descriptions [34513]).
CURRENTOBJECT, COMPONENTNAME, AND CURRENTFIXATIONDURATION - These three columns in the GazeData.txt file occasionally carry information about the last E-Object from the previous trial to the start of the next trial (BUG: TET-enabled experiments occasionally carry CurrentObject, ComponentName and CurrentFixationDuration to the next Procedure [34509]).
TETGAZEDATASETPROPERTYMATCH AND TETGAZEDATASETPROPERTYMATCHLIMIT PACKAGEFILE - An incorrect description in the "remarks" section of the PackageFile leads to unexpected values written to the GazeData file (BUG: Mistake in TETGazeDataSetPropertyMatch and TETGazeDataSetPropertyMatchLimit PackageFile documentation [37387]). Error occurs when term1 and matches1 are blank (BUG: Runtime error occurs with TETGazeDataSetPropertyMatch and TETGazeDataSetProperMatchLimit [34510]).
MOVIE START POSITION ERROR - The error presented when the Start Position is a non-zero value is incorrect (BUG: Error text for a TPL movie Display Event with a non-zero Start Position is incorrect [37703]).
VIDEO FILE ENCODING - Certain movie file encodings cause errors (ERROR: Incompatible movie file encodings cause error during UploadMedia [39897]).
TOBII PRO LAB (VERSION 1.207) - This version of Tobii Pro Lab results in an error because the application does not disconnect after running a previous session (BUG: Tobii Pro Lab (version 1.207) does not disconnect when running consecutive sessions [40769]).