This article applies to:
E-Prime 2.0
This bug has been corrected in E-Prime 2.0 (2.0.10.353).
Symptoms
When using E-Prime 2.0 Professional to open E-Prime 2.0 Standard experiment (.es2) files, you are prompted to either maintain the Standard file format or convert to the Professional file format:
If you convert the file, E-Prime opens the file in E-Studio as a Professional edition file. However, some E-Prime 2.0 Professional features, including Task Events and Package File calls, are not available.
Solution
Update to E-Prime 2.0.10.353 or later.
Workaround
This workaround is intended only for those who are unable to update to the version of E-Prime that contains the bug fix:
Close E-Studio, then launch E-Studio and open the experiment file. All Professional features will be restored.
See Also:
RELEASE INFO: FAQ about E-Prime Versions [19564]
INFO: Conversion action dialog options added to the Tools...Options area of E-Studio [18329]
Comments
0 comments
Please sign in to leave a comment.