Clock GUI
E-Prime provides the ability to choose from available clocks via the E-Studio GUI. The Clock is specified from the Timing tab on the Experiment Object Properties:
When the E-Prime Realtime Clock is selected, then no additional settings are required unless flagged by Experiment Advisor.
When the SNTP Realtime Clock is selected, then additional configuration settings are required. A SNTPClockExtension.ini file must reside in the same location as the SNTPClockExtension (defaults to C:\Program Files (x86)\E-Prime 3.0\Program). It is recommended to place the SNTPClockExtension.ini in the My Experiments folder for easier editing for regular users (the admin security level is needed to edit files located in Program Files).
IP | IPv4 address of NTP server (default: invalid/error) |
Port | Port to connect to (default: 123) |
PollInterval | Time in milliseconds to poll NTP Clock Server |
Timeout | Time in milliseconds to wait for response from NTP Clock Server |
Affinity | Enable/disable logging (default: 1) |
Log | Prohibit servers Ips outside RFC1918 local rangers (default: 1) |
LocalOnly | 0/1 - Used to prohibit settings to be performed in My Experiments. |